SPECIFICATIONS |
||||||||||
MODEL |
6303 |
6306 |
6309 |
6315 |
6330 |
6360 |
6390 |
63120 |
||
INPUT |
||||||||||
Phase |
1ø |
3ø |
||||||||
Voltage |
230Vac±15% |
220/380Vac±10% |
||||||||
Frequency |
47-63Hz |
|||||||||
OUTPUT |
||||||||||
Max. Power |
Single-Phase |
1KVA |
2KVA |
3KVA |
5KVA |
10KVA |
20KVA |
30KVA |
40KVA |
|
Total Power |
3KVA |
6KVA |
9KVA |
15KVA |
30KVA |
60KVA |
90KVA |
120KVA |
||
Max. Current (r.m.s) |
0-150V |
8.4A |
16.8A |
25.2A |
42.0A |
84.0A |
168.0A |
252.0A |
336.0A |
|
, Single-Phase*1 |
0-300V |
4.2A |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
|
Max. Current (r.m.s), Single-Phase |
0-300V |
4.2A |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
|
(Option 0-600V)*2 |
0-600V |
2.1A |
4.2A |
6.3A |
10.5A |
21.0A |
42.0A |
63.0A |
84.0A |
|
Phase |
3ø/4W |
|||||||||
Total Harmonic Distortion (T.H.D) |
< 1% at 47-63Hz (Resistive Load) |
|||||||||
Crest Factor |
>3 |
|||||||||
Line Regulation |
± 0.1V |
|||||||||
Load Regulation |
L - N : ± (0.5% of output +0.5V) / L - L : ± (1% of output +1V) at Resistive Load |
|||||||||
Deviation of phase angle |
120° ? ±1° at Load Balance, 120° <= ±2.5° at 100% Load Unblance |
|||||||||
Response Time |
< 2 msec |
|||||||||
SETTINGS |
||||||||||
Voltage |
Range |
0-150V/0-300V Selectable or 0-300V/0-600V Selectable(Option 0-600V) |
||||||||
Resolution |
0.1V |
|||||||||
Accuracy |
±(1% of setting + 2counts) |
|||||||||
Frequency |
Range |
47.0-63.0Hz Full Range Adjust |
||||||||
Resolution |
0.1Hz |
|||||||||
Accuracy |
±0.02% of setting |
|||||||||
MEASUREMENT |
||||||||||
Voltage |
L - N Range |
0.0-300.0V / 0.0-600.0V(Option 0-600V) |
||||||||
L - L Range |
0.0-520.0V / 0.0-1040V(Option 0-600V) |
|||||||||
Resolution |
0.1V / 0.2V |
|||||||||
Accuracy |
± (1% of reading + 2counts) |
|||||||||
Frequency |
Range |
47.0-63.0Hz |
||||||||
Resolution |
0.1Hz |
|||||||||
Accuracy |
±0.1Hz |
|||||||||
Current (r.m.s) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
||||||
H |
3.00-35.00A |
30.00-350.0A |
||||||||
Resolution |
L |
0.001A |
0.01A |
|||||||
H |
0.01A |
0.1A |
||||||||
Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
|||||||
H |
± (1% of reading +1count) |
± (1% of reading +1count) |
||||||||
Current (r.m.s) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
||||||
(Option 0-600V) |
H |
3.00-35.00A |
30.00-350.0A |
|||||||
|
Resolution |
L |
0.001A |
0.01A |
||||||
|
H |
0.01A |
0.1A |
|||||||
|
Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
||||||
|
H |
± (1% of reading +1count) |
± (1% of reading +1count) |
|||||||
Power |
Range |
L |
0.0-350.0W |
0.000-3.500KW |
||||||
H |
300-4000W |
3.00-40.00KW |
||||||||
Resolution |
L |
0.1W |
0.001KW |
|||||||
H |
1W |
0.01KW |
||||||||
Accuracy |
L |
± (1.5% of reading +5counts) |
||||||||
H |
± (1.5% of reading +1count) |
|||||||||
Power Factor |
Range |
0.000-1.000 |
||||||||
Resolution |
0.001 |
|||||||||
Accuracy |
W / V x A , Calculated and displayed to three significant digits |