S-350-24單路輸出開關(guān)電源
| |||||||||||
型號(hào) | S-350-5 | S-350-7.5 | S-350-12 | S-350-13.5 | S-350-15 | S-350-24 | S-350-27 | S-350-48 | |||
輸出 | 直流輸出電壓 | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V | ||
輸出電壓容差(注3) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |||
額定輸出電流(注4) | 50A | 40A | 29A | 25.8A | 23.2A | 14.6A | 13A | 7.3A | |||
輸出電流范圍 | 0-50A | 0-40A | 0-29A | 0-25.8A | 0-23.2A | 0-14.6A | 0-13A | 0-7.3A | |||
輸出功率 | 250W | 300W | 348W | 348.3W | 348W | 350.4W | 351W | 350.4W | |||
紋波及噪音(注2) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |||
直流電壓可調(diào)范圍 | -10%,+12% | ±20% | -16%,+10% | -12%,+11% | -10%,+20% | -16%,+10% | -4%,+18% | -15%,+17% | |||
啟動(dòng)、上升、保持時(shí)間 | 200ms,50ms,20ms滿載 | ||||||||||
輸入 | 輸入電壓范圍 | 90~132 VAC/180~264VAC 47~63 Hz;由開關(guān)選擇254~370VDC | |||||||||
交流輸入電流 | 6.5A/115 V 4A/ 230 V | ||||||||||
效率 | 74% | 76% | 76% | 79% | 78% | 81% | 82% | 83% | |||
沖擊電流 | 冷啟動(dòng)電流50A/115V 50A/230V | ||||||||||
漏電流 | <3.5 mA/240VAC | ||||||||||
保護(hù)特性 | 過載保護(hù) | 105%~135% | |||||||||
保護(hù)方式:電流限制 ,自動(dòng)恢復(fù) | |||||||||||
過電壓保護(hù) | 115%~135% | ||||||||||
保護(hù)方式:電壓限制 ,自動(dòng)恢復(fù) | |||||||||||
風(fēng)機(jī)開/關(guān)控制 | RT3≥55℃風(fēng)機(jī)開,≤45℃風(fēng)機(jī)關(guān),≥80℃切斷輸出 (5~7.5V) | ||||||||||
RT3≥65℃風(fēng)機(jī)開,≤55℃風(fēng)機(jī)關(guān),≥80℃切斷輸出 (12~15V) | |||||||||||
RT3≥70℃風(fēng)機(jī)開,≤60℃風(fēng)機(jī)關(guān),≥85℃切斷輸出 (24~48V) | |||||||||||
環(huán)境 | 工作溫度、濕度 | -10℃~+60℃;20%~90 %RH | |||||||||
保存溫度、濕度 | -20℃~+85℃;10%~95 %RH | ||||||||||
抗震性 | 10~500Hz,2G 10min./1周期,時(shí)長60分鐘,各軸 | ||||||||||
安全 | 耐壓性 | 輸入輸出間:1.5KVAC 輸入與地:1.5KVAC 輸出與地:0.5KVAC | |||||||||
絕緣電阻 | 輸入輸出間,輸入與地,輸出與地: 100M Ohms/500VDC | ||||||||||
符合標(biāo)準(zhǔn) | 安全標(biāo)準(zhǔn) | 符合UL1950 | |||||||||
EMC標(biāo)準(zhǔn) | Drsign refer to FCC Part15 J Conduction Class A | ||||||||||
其它 | 重量 | 1.1.5Kg | |||||||||
包裝 | 12pcs/14.3Kg/0.93CUFT | ||||||||||
備注 |
|