噴涂硬泡聚氨酯保溫層
Spraying hard foam polyurethane thermal insulation layer
開啟聚氨酯噴涂機將硬泡聚氨酯均勻地噴涂于墻面之上,當厚度達到約10mm時,按300mm間距、梅花狀分布插定厚度標桿,每平方米密度宜控制在9~10支。聚氨酯噴涂機廠家http://www.mxfpj.cn/
Open polyurethane coating machine will be hard foam polyurethane spray evenly on the wall, when the thickness of about 10 mm, according to the thickness of 300 mm spacing, the plum blossom shape distribution ChaDing benchmarking, density of every square metre should be controlled in 9 ~ 10.
然后繼續(xù)噴涂至與標桿齊平(隱約可見標桿頭)。施工噴涂可多遍完成,每次厚度宜控制在lOmm以內。水簾噴漆臺 http://www.jnshibao.com Then continue to spray to flush with benchmark (visible) benchmarking. Construction coating can be done more times, each time the appropriate thickness control within lOmm. 修整硬泡聚氨酯保溫層
Dressing rigid polyurethane thermal insulation layer
噴涂20min后用裁紙刀、手鋸等工具清理、修整遮擋部位以及超過保溫層總厚度的突出部分。
After 20 min spraying with paper cutting knives, hand saw tools such as cleaning, finishing block area and more than outstanding part of the insulation layer thickness of total.
噴刷聚氨酯界面砂漿
Spray polyurethane interface mortar
聚氨酯保溫層修整完畢并且在噴涂4h之后,用噴斗或滾刷均勻地將聚氨酯界面砂漿噴刷于硬泡聚氨酯保溫層表面。酒店活動隔斷http://www.sdkeyou.com/
Polyurethane thermal insulation layer was trim and after spraying 4 h, with spray pipe or rolling brush evenly spray polyurethane interface mortar on the surface of hard foam polyurethane thermal insulation layer.